Page 1 of 8 reference sp0504r01 ver 1 reference owner. Pdf file text and xml file measurement of oil temperature bluetooth and usbconnection printout of test results pc software ba control center manage up to 4 bas from your pc simultaneously start the test sequence remotely from your pc create user defined test sequences and implement them via bluetooth or usb. Dissolved gas analysis dga is the study of dissolved gases in transformer oil insulating materials within transformers and electrical equipment break down to liberate gases within the unit. The automatically generated test reports are provided in pdfformat and are stored on a usb stick. Job safety analysis power transformer testing check this is the latest process zone version before use. If unequal voltages are used, a circulating current exists in the closed network. Maintenance and repair of medium power transformers. Specific transformer oil test method availability will vary depending upon location. Transformer oil testing is a proven loss prevention technique that should be a part of any condition based predictive maintenance program.
Oil spill kit test equipment will vary form site to site. Transformer oil testing by robert turcotte, manager, electrical loss control the hartford steam boiler inspection and insurance company the value of transformer oil testing transformer oil testing is a proven loss prevention technique which should be a part. For a high voltage pulse power supply of 140kv amplitude, rise time 1usec, fall time 1usec, pulse width 6 usec and prf is 10 hz. Basics, maintenance, and diagnostics ix contents continued page 6. There is no rule that says what specific protection scheme is appropriate for a given transformer application. Along with the oil sample quality tests, performing a dissolved gas analysis dga of the insulating oil is useful in evaluating transformer health. A transformer is an electrical apparatus designed to convert alternating current from one voltage to another. Testing of power transformers 7 remember school days. This paper presents results of dc resistivity measurements of oil samples including a mineral oil and a.
Dissolved gas in oil analysis, screen tests, moisture content, furan compounds, and pcb. Gray transformer chemistry services introduction the fault free operation of power transformers is a factor of major economic importance and safety in power supply utilities and. Immediately prior to despatch of the transformer from the manufacturers works, the magnetic circuit shall be pressure tested for 1 minute at 2000 v ac between the core and earth. Routine testing of transformer oils and insulating oils on a regular schedule is an accepted industry. The objective of the research is to use the furan compound analysis in operating oil transformer to. What links here related changes upload file special pages permanent link page. Transformer design drytype and cast resin, protection methods are being referred and more also included in the specific research document. Skraceni maintenance and repair of medium power transformers. Breakdown voltage test for transformers oil as per iec 60296 type special tests as per iec60076 1 temperature rise test. Procedures for drawing transformer oil samples general sampling electrical insulating oil for laboratory analysis requires care to ensure that the sample is representative of the product being sampled. Transformer oil analysis bureau veritas commodities. However, regardless of whether it was created by the removal from service, the end of the test e. It is intended to use this oil as an electrical insulation and oil as coolant in applications such as transformers, reactors, tap changes, switchgear, oil filled capacitors etc.
Ergon energy corporation limited abn 50 087 646 062. Transformer oil testing quick, simple and onsite b2hv. Oil tests in the shop or laboratory would be carried out at room temperature 20o c. There is some tendency to tie protection schemes to the mva and primary kv of a transformer. In chapter three and four, an extended discussion on the transformer oil properties is made, taking into consideration the eleven most important ones. After a transformer has been received at its final destination, it is advisable to put it full of oil on its permanent place, even if it is not going to be placed in operation immediately.
However, in california, used oil is managed as hazardous waste until tested to show it is not hazardous. The distribution of these gases can be related to the type of electrical fault, and the rate of gas generation can indicate the severity of the fault. Coconut oil as an alternative to transformer oil pdf. Our procedures allow for complete traceability from the time a sample is created using our online ms oil lims software until we produce your final test report. What is the minimum value of breakdown voltage of transformer oil. This oil shall also make an important contribution to the efficiency of the solid insulation by penetrating into and filling the spaces. If regularly conducted, oil analysis allows identification of specific fault conditions that may be developing. If this is not possible, the transformer has to be placed in a dry place and the transformer must be filled with oil. If oil becomes acidic, water content in the oil becomes more soluble to. Transformer oil, a type of insulating and cooling oil used in transformers and other electrical. However, any 50 hz transformer will operate on a 60 hz service. Oil gas tests and samples testing the insulating oil or gas medium is required to ensure the insulation performs as intended by themanufacturer.
Transformers can selfdestruct if neglected over time and failure to conduct regular transformer oil testing can allow problems to go undetected. Transformer oil analysis basic introduction by n robinson, wearcheck as blood tests disclose ones state of health, so oil analyses disclose the condition of a transformer. Current state of transformer fra interpretation pdf free. Same nine samples were investigated for acidity value by means of. One must assure that the test cell is clean and it is a wise precaution to bleed the sampling tube to assure a representative sample. This early warning system can allow management to identify maintenance priorities, plan work assignment schedules, and order necessary parts and materials. Transformer oil purchase specifications developed under the auspices of the doble oil committee march, 2017 composition this specifications covers new insulating oil for general applications for liquidfilled electrical equipment, which are manufactured from mineral crude, which may be either naphthenic, which has a very low naturally. It applies to oil delivered to the agreed point and time of delivery, intended for use in transformers, switchgear and similar electrical equipment in which oil is required as an insulant and for heat transfer.
Understanding insulation resistance testing pdf 0712 technical assistance 800 34391. High quality level for more reliability customer benefits minera oil immersed transformers up to 5 mva 36 kv the right tune. It can be designed to step up or step down voltages and works on the magnetic induction principle. Whatever the transformer type you require, you will find your solution in minera. Also there is detailed analysis about the consisting of a distribution transformer. Consult state and local regulations regarding the proper handling of used oil. Requires 1 litre of oil in a polyethylene container.
Because a test confirms what you know, if you can apply in real life what you have learned in a classroom, under strict, rigorous and controlled conditions. The acidity level of transformer oil is measured as per british standard bs2000 part 1. What links here related changes upload file special pages permanent. Transformer oil test methods include astm, bs,and other recognized transformer oil analysis testing procedures. Some of the most common tests for transformer oil are as follows. This test is similar to tests 1 and 2, but as applied to a three phase transformer for phase identification and phase continuity check. These include the chemical and causes of the specific physical properties of the test oils. The test connection arrangement is shown in figure 2 c. Transformer oil or insulating oil is an oil that is stable at high temperatures and has excellent. Gerald sellers lab manager shermco oil analysis laboratory. From the test results it shall be identified that acidity content is high for degraded oil. Complete tests 1 and 2 for each winding of a threephase transformer individually with the remaining windings kept open. Morgan schaffer pioneered dissolved gas analysis dga in america. Transformer oil analysis provides a highly accurate indication of the internal condition of a transformer.
Also information about some types of transformers are gathered as well as distribution transformer connections installations. No characteristics requirements method of test 1 appearance the oil shall be clear and transparent and free from. Basics, maintenance, and diagnostics vii contents continued page 4. Each delta star distribution transformer is given the following tests to ensure high quality. Transformer oil analyst software, the fault condition of the transformer can be diagnosed. The installation and testing of the transformer verifies its. Highvoltage transformers are some of the most important and expensive pieces of. Before attempting to draw the sample identify the type of cooling liquid in the transformer. This international standard covers specifications and test methods for unused mineral insulating oils. Importance of transformer processes the way a transformer is handled and the procedures that are used to receive, assemble, process and test the transformer are of fundamental importance to the long life of the transformer.